B0-force · Clause 11
Displacement force produced by the static magnetic field () has the potential to cause unwanted movement of a device containing magnetic materials. AIMDs generally contain paramagnetic, diamagnetic, and ferromagnetic materials. For a paramagnetic, diamagnetic, or ferromagnetic material below saturation, the location of maximum displacement force is at the point where the product of the magnitudes of the magnetic field () and the spatial gradient of the magnetic field () is at a maximum. The same is true for paramagnetic material above saturation. For ferromagnetic material above the magnetic saturation point, the maximum displacement force will occur at the location where is a maximum. These locations are off the central axis of the bore of an MR scanner.
— ISO/TS 10974:2018, Clause 11
Principle
(Pending)
Solution
(Pending)
Experiment
(Pending)
Conclusion
(Pending)
References
Patents
- AU2007276742B2_MED-EL ·
rotatable-magnet— 通过将永磁体平行于患者身体轴放置,减少或消除MRI中B0场对中耳植入磁体的扭矩和退磁效应,同时使线圈在MRI前切换至非活动状态以避免位移 - EP2824943B1_MED-EL ·
rotatable-magnet— 球形磁体可自由旋转对齐任意方向B0场消除扭矩和退磁,反并联线圈抵消RF感应电压,与AU2011247825B2为同一专利家族 - EP2869892B1_MED-EL ·
rotatable-magnet— 采用径向对称植入磁铁排列,使净磁偶极矩接近零,降低MRI中B0场产生的扭矩,同时减少成像伪影(「降低位移力」raw 无直接出处,仅由「净矩零⇒一阶平动力零」一步推导) - EP3138605B2_MED-EL ·
rotatable-magnet— 平面盘状或切口盘状植入磁铁,磁偶极平行于线圈外壳平面,可旋转以在MRI中自对准B0场,降低扭矩和退磁风险 - EP4008397B1_Advanced-Bionics ·
rotatable-magnet— 头件磁体通过重力自对齐实现N-S方向与重力方向一致,从而最大化侧向保持力,同时解决MRI磁场下磁体扭矩导致的位移问题 - EP4074373B1_MED-EL ·
rotatable-magnet— 平面盘状或切口盘状可旋转植入磁铁,磁偶极平行于线圈外壳平面,MRI中自对准B0场,消除扭矩和退磁,减少伪影 - US10279186B2_Medtronic ·
mri-mode-switching— 自动化兼容性验证系统,通过多源数据采集和分析确认AIMD与MRI设备兼容性并配置安全模式 - US10398891B2_Cochlear ·
housing— 完全密封磁铁于硅胶体内并可术后移除更换,以兼容MRI检查 - US10646712B2_Advanced-Bionics ·
rotatable-magnet— 采用双盘状磁体各含N/S/非磁区域,自由旋转使MRI下AM区域对齐消磁,减少磁体体积从而降低扭矩,同时维持日常N-S-N-S条纹磁化保持头件吸力 - US10674287B2_Cochlear ·
rotatable-magnet— 磁铁置于通信线圈封闭边界外侧,磁铁可旋转对齐B0场,减少MRI中扭矩与伪影 - US10893937B2_Cochlear ·
housing— 聚合物外壳+金属镀层磁铁组件替代钛全金属外壳,实现MRI兼容与体液防护 - US11012796B2_Cochlear ·
other— 通过可移动磁组件调节外部与植入磁铁间的磁阻,改变保持力以适应不同活动强度 - US11426593B2_MED-EL ·
housing— U形磁铁夹持结构使植入磁铁可滑动穿过线圈外壳凹槽进入中心容腔,实现小切口手术移除/更换;本篇对 image-artifact 的主路径为术前经小切口取出磁体,可旋转仅为 claim 7/8 可选支路(照 US 8,634,909 实施、仅作用于力矩) - US12383739B2_Cochlear ·
rotatable-magnet— 通过板+弹性材料组合,将MRI扭矩转化为板的平移分离,利用弹性体张力限制磁体旋转 - US20250001186A1_Advanced-Bionics ·
rotatable-magnet— 仅两根固定间距的径向磁化长条形磁铁,位于可旋转框架内,可绕纵轴相对框架旋转以在3D MRI磁场中对齐 - US20250050102A1_Advanced-Bionics ·
rotatable-magnet— 非磁性间隔件+气密密封壳体内的至少一个磁铁,以及旋转框架内可绕纵轴旋转的多根径向磁化磁铁,用于在3D MRI磁场中对齐 - US20250229091A1_Cochlear ·
other— 柔性接触面在磁吸力下形变贴合头皮;植入磁性材料316可配置为抗磁(diamagnetic)以兼容 MRI - US20250381392A1_Cochlear ·
other— 压力施加部分在磁体位置施加有针对性的压力,支撑部分在不同位置支撑,通过可调皮带固定装置将整体加压以抑制MRI磁场中的磁体运动脱位。 - US6141591A_Boston-Scientific ·
other— 无磁铁植入式刺激器系统,通过外科工具模板实现植入线圈与外部发射线圈的精确对准,消除MRI不兼容的植入磁铁 - US7609061B2_MED-EL ·
mri-mode-switching— 利用MRI扫描仪的强磁场本身对植入磁铁进行消磁和再磁化,无需手术移除磁铁即可进行MRI检查 - US8733494B1_Cochlear ·
non-magnetized— 以植入端非磁化铁磁性/亚铁磁性环形构件替代传统植入磁体,专利断言MRI扫描时无扭矩施加、位移力降低、无法退磁、伪影减少(四项均为定性断言、无支撑数据),外部磁铁与植入端非磁化构件的对应环形形状实现经皮线圈自对准;物理上实际缓解b0-torque/b0-force/image-artifact,pool。 - US8744106B2_MED-EL ·
rotatable-magnet— 浮动质量换能器采用内杆磁铁+外环形磁铁的反向磁场磁对结构,使合成磁场相互抵消以最小化与外部磁场的相互作用 - US8768480B2_Oticon-Medical ·
housing— 植入式皮下装置采用空心陶瓷冠形外壳容纳电子器件和线圈,中心腔室可逆地放置可提取磁铁,磁铁靠近皮肤以增强与外部磁铁的吸引力,同时磁铁可移除以便MRI检查 - US9008788B2_Medtronic ·
mri-mode-switching— 通过周期性遥测信号指示MRI环境存在,IMD接收到后进入暴露模式,未接收到预定时间后退出。 - US9066188B2_Oticon-Medical ·
housing— 一种骨传导助听器,采用耳钩承载设备重量,通过磁力压缩部件将振动经皮肤传递到颅骨,皮下磁铁可旋入颅骨并可移除以便MRI检查 - US9844666B2_Advanced-Bionics ·
housing— 嵌入式保持架/巢穴结构(PEEK/聚砜)+可拆卸磁铁壳体(钛密封),通过螺纹/卡扣/法兰多种方式 retain磁铁,低场MRI可保留,高场MRI可移除 - US9919158B2_Medtronic ·
mri-mode-switching— IMD通过传感器检测MRI产生的破坏性能量场,确定实际或预测效应(如温度变化、阈值变化),并根据效应调整操作参数(如从同步起搏切换为异步起搏模式、调整起搏幅度/脉宽),以减轻MRI对设备的影响。 - WO2003092326A1_Cochlear ·
rotatable-magnet— MRI兼容的人工耳蜗植入物,通过磁体保持装置将磁体固定在天线线圈的硅树脂中,使磁体在MRI扫描时可移动或移除以减少伪影和力/扭矩 - WO2023119156A1_Cochlear ·
rotatable-magnet— 磁铁在密闭腔体内独立旋转(达360°)、移动受外磁场约束(权项19),随 B0 自适应取向释放扭矩 - WO2026047489A1_Cochlear ·
rotatable-magnet— 热融/焊接连接不同磁化方向的磁铁部分,防止在MRI B0磁场中相对运动和蝶形翻转,降低植入体扭矩
Papers
(Pending)
Standards
(Pending)
Regulatory
(Pending)
Vendor
(Pending)
News
(Pending)